TRION-CNT technical indicators |
Input channel | 6 advanced counter or 18 digital inputs (TRION-CNT-6-L1B) |
counter mode
- Waveform timing
- Sensor modes
- Event counting | Period, frequency, pulse width duty cycle and edge separation
Encoder (angle and linear)
Basic event counting,gated counting, up/down counting and encoder mode (X1,X2 and X4) |
Voltage to ground EN 61010-2-30 | 33 Vaws,70Vc,46,7 VPEAK |
compatibility | Adjustable trigger levels |
Insulation voltage (between channels and between channels to chassis) | 500 Vc |
Input coupling | DC and AC(1Hz) ACfor input A only |
Input impedance (ground referenced) | 1MQ/5pF |
sampling rate | 2 MS/s per channel |
Bandwidth (- 3dB) | 5 MHz |
Trigger adjustable range | 0 to 50 V |
Trigger resolution | 12 mV |
Trigger level precision | ±20 mV±1% of threshold/retrigger level |
Overvoltage protection | ±100 V |
Maximum DC voltage @ AC coupling | ±50VDC |
Counter resolution | 32-bit |
Counter time base | 80 MHz |
Time base precision | Within DEWE2 system | Typ.10 ppm; max. 50 ppm |
Within DEWE3 system | Typ.2 ppm; max. 10 ppm |
Maximum input frequency | 10 MHz |
Sensor supply | 5V(600 mA)and 12V(600 mA),not isolated |
power waste | 5 W |
weight | Approx. 240 g |