With A/D converter Trion3 And Trion module
Our multi-channel signal conditioning module provides separate A/D conversion on each channel, and has an anti aliasing filter, which can reach 24 bit resolution. All analog input modules can realize synchronous sampling. Replaceable TRION 3 and TRION modules can easily and flexibly Data acquisition system Upgrade or build - just plug them into your appropriate DEWETRON DAQ data collection system.
There are two module families: the high-speed TRION3 module is only compatible with the DEWE3 chassis. However, the TRION module can be used in the DEWE3 and DEWE2 chassis.
DVC has the following different types of data acquisition board cards to choose from:
Analog input module
Power module
Sub module
Digital input module
Analog output module
Analog input module
Digital input module
Power measurement module
model |
| passageway | sampling rate | resolving power | Interface type |
---|
TRION3 -1810M-POWER
| |
8 (4U/4I) | 10 MS/s | 18-bit | Fixed: 4 x banana head CAT III 1000 V – Optional: 4 x Sub-Modules |
TRION3 -1820-POWER
| | 8(4U/4I) | 2 MS/s | 18-bit | Fixed: 4 x bananas Head CAT III 1000 V – Optional: 4 x Sub-Modules |
TRION-1820-POWER
| | 8(4U/4I) | 2 MS/s | 24-bit | Fixed: 4 x bananas Head CAT III 1000 V – Optional: 4 x Sub-Modules |
TRION-1810-HV
| | 8 (4U/4I) | 1 MS/s | 24-bit | Fixed: 4 x bananas Head CAT III 1000 V – Optional: 4 x Sub-Modules |
TRION3 -1810-SUB-8
| | eight | 1 MS/s | 18-bit | Fixed: 0 – Optional: 8 x Sub-Modules |
Analog output module
Sub module
| model | picture | range | Safety level | bandwidth | Interface |
---|
Current input sub module (direct or sensor)
|
| 20 A module TRION-POWER-SUB-CUR-20A-1B
| | 20 A RMS (±40 A PEAK ) | CAT II 600 V, unfused | 300 kHz | Safety banana (male) |
| 2 A module TRION-POWER-SUB-CUR-2A-1B
| | 2 A RMS (±4 A PEAK ) | CAT II 600 V, unfused | 300 kHz | Safety banana (male) |
| 1 A module TRION-POWER-SUB-CUR-1A-1B | | 1 A RMS (±2 A PEAK ) | CAT II 600 V, unfused | 300 kHz | Safety banana (male) |
| 0.2 A module TRION-POWER-SUB-CUR-02A-1B | | 0.2 A RMS (±0.4 A PEAK ) | CAT II 600 V, unfused | 300 kHz | Safety banana (male) |
| Seamless auto-range module TRION-SUB-XA | | COMING SOON | Safety banana (male) |
Voltage input sub module |
| 1 V module TRION-POWER-SUB-dLV-1V
| | 1 V RMS (±2 V PEAK ) | Non isolated, depending on current sensor | 5 MHz | D-SUB-9 socket |
| 5 V module TRION-POWER-SUB-dLV-5V
| | 5 V RMS (±10 V PEAK ) | 5 MHz | D-SUB-9 socket |
| Clamp input module TRION-POWER-SUB-dLV-1
| | 5 V RMS (±10 V PEAK ) | 150 kHz | D-SUB-9 socket |
| 600 V module TRION-SUB-600V
| | 600 V RMS (±1500 V PEAK ) | CAT II 600 V, Electrical isolation | 300 kHz | Safety banana |
| 5 V module TRION-SUB-5V | | 5 V RMS (±10 V PEAK ) | CAT II 600 V, Electrical isolation | 300 kHz | Safety banana |
| Seamless auto-range module TRION-SUB-XV | | COMING SOON | Safety banana |