Do you need a rack mounted DAQ data acquisition system? Then you can use our rack mounted data acquisition mainframe. Thanks to the easy to integrate 19 inch installation kit, the fan slot is easy to maintain and silent cooling at the front. Our DAQ system of data acquisition host is completely modular. It is used for analog quantity, digital quantity, CAN input, counter, etc. through user replaceable TRION (3) module. The resolution is optional, up to 24 bits, and can be upgraded.
Product features:
8 TRION3 or TRION boards can be inserted
64 analog output channels
8 sensor power supply interfaces
Rack or desktop data acquisition host
Silent cooling and easy maintenance fan slot
Support synchronization of multiple DEWE3-RM series hosts, with a maximum speed of 10Gbit
Raw data is stored without gaps, up to 1GB/s
Bandwidth up to 1000MB/s
19 "installation kit available
Connectivity and scalability
SYNC-CLOCK ™ Synchronize all signal sources:
TRION ™ modular
video camera
FlexRay interface
Global Positioning System (GPS)
Scalability
DEWE2 front end enclosure (for more TRIONS ™ Slot scenario)
CPAD/EPAD (for static signal low sampling input)
Software
DEWE3-RM8 can be used in OXYGEN With the cooperation of measurement software, its potential can be brought into full play.
DEWETRON Interface of measurement software OXYGEN
Trion3 ™ High speed module selection guide
Select different multi-channel TRION3 ™ High speed sampling module. TRION3-18xx-MULTI The module is 10 times faster than the same type of acquisition module.
model |
| passageway | Sampling [kS/s] | Sensor supply | Voltage range | electric current | IEPE | Bridge [F/H/QU] | Thermocouple | charge | RTD | Others |
---|
TRION3-1820-MULTI | | 4 or 8 ISO | 2000 / 24 | 0-24 V | ±100 | | | | | | | CAN, CNT, TEDS |
TRION3-1850-MULTI | | 4 or 8 ISO | 5000 / 18 | 0-24 V | ±100 | | | | | | | CAN, CNT, TEDS |
TRION3-1810M-POWER-4 | | 4 U + 4 I | 10000 / 18 | +9 V | 1000 VRMS | |
|
|
|
|
|
|
Trion ™ Module Selection Guide
Select different multi-channel TRION ™ modular. The user switchable module provides analog conversion on each channel.
model |
| passageway | sampling rate [kS/s] | sensor power supply | Voltage input | electric current | IEPE | bridge [F/H/QU] | Thermocouple | charge | RTD resistance | Others |
---|
TRION-2402-MULTI | | 4/8 ISO | 204 / 24 | 0-24 V | ±100 |
| | | | | | CAN, TEDS |
TRION-1820-MULTI | | 4 ISO | 2000/24 | 0-24 V | ±100 | | | | | | | CAN, CNT, TEDS |
TRION-1820-POWER -4 | | 4 U + 4 I | 2000 / 18 | +9 V | 1000 VRMS | |
|
|
|
|
| Replaceable current module (20A, 2A, 0.2A, 5V) |
TRION-1600-dLV | | 16 or 32 | twenty | 5 V, 12 V | ±5 / ±10 |
|
|
|
|
|
| 2x counter, CAN-bus, 8x DI, 4x DO, RS485, 2x alarm out |
TRION-1603-LV-6-L1B | | 6 ISO | 250 / 16 | 1-28 V | ±100 | |
|
|
|
|
| TEDS |
TRION-1603-LV-6-BNC | | 6 ISO | 250 / 16 | - | ±100 |
|
|
|
|
|
|
|
TRION-1620-LV-6-L1B | | 6 ISO | 2000 / 24 | 1-28 V | ±100 | |
|
|
|
|
| TEDS |
TRION-1620-ACC | | 6 ISO | 2000 / 24 | 4 / 8 mA | ±100 |
| |
|
|
|
| Tacho |
TRION-1802-dLV | | 16 or 32 | 200 / 100 | 5 V , 12 V | ±5 / ±10 |
|
|
|
|
|
| 2x counter, CAN-bus, 8x DI, 4x DO, RS485, 2x alarm out |
TRION-2402-dACC | | 6/8 DIFF | 204 / 24 | 0.1-24 mA | ±100 |
| |
|
|
| | Tacho, TEDS |
TRION-2402-dSTG | | 6/8 DIFF | 204 / 24 | 0-13 V | ±10 |
| | |
|
| | TEDS |
TRION-2402-V | | 4/8 ISO | 204 / 24 |
| ±1000 |
|
|
|
|
|
|
|
TRION-BASE | | 16 DI(O) + 2 CNT | 2000 / - | 5 V, 12 V |
|
|
|
|
|
|
| DIO, IRIG-B DC, Counter |
TRION-TIMING-V3 | | 8 DIO + 1 CNT | 2000 / - | 5 V, 12 V |
|
|
|
|
|
|
| DIO, IRIG full, GPS 1Hz, Counter |
TRION-CNT | | 6 ISO | 204 / - | 5 V, 12 V |
|
|
|
|
|
|
| Counter |
TRION-CAN | | 2/4 ISO | 1000 kBit/s | 5 V, 12 V |
|
|
|
|
|
|
| CAN |
TRION-DI-48 | | 48 ISO | 3000 / - | 5 V |
|
|
|
|
|
|
| Digital Input |
TRION-VGPS-20-100-V3 | | 8 DIO + 1 CNT | 2000 / - | 5 V, 12 V |
|
|
|
|
|
|
| DIO, Counter, GPS 100Hz |
CPAD/EPAD module selection guide
Connect external, multi-channel modules, integrate analog signal conditioning and A/D converters in an extremely sturdy box that can be daisy chained.
model |
| passageway | Sampling rate [kS/s] | Interface | Voltage range [V] | electric current | Thermocouple | Thermal resistance RTD |
---|
CPAD3 -V8 | | 8 ISO | 100 / 20 | CAN 2.0B | ± 50 |
|
|
|
CPAD3-TH8 | | 8 ISO | 100 / 20 | CAN 2.0B |
|
| |
|
CPAD2-V8 | | 8 ISO | 12 / 24 | CAN 2.0B | ± 50 |
|
|
|
CPAD2-TH8 | | 8 ISO | 12 / 24 | CAN 2.0B |
|
| |
|
CPAD2-RTD8 | | 8 ISO | 12 / 24 | CAN 2.0B |
|
|
| |
CPAD2-LA8 | | 8 ISO | 12 / 24 | CAN 2.0B |
| |
|
|
EPAD2-V8 | | 8 ISO | 12 / 24 | RS-485 | ± 50 |
|
|
|
EPAD2-TH8 |
| 8 ISO | 12 / 24 | RS-485 |
|
| |
|
EPAD2-RTD8 | | 8 ISO | 12 / 24 | RS-485 |
|
|
| |
EPAD2-LA8 | | 8 ISO | 12 / 24 | RS-485 |
| |
|
|