Shanghai Beiying Electronics
contact us
 Shanghai Beiying Electronics
Email: [email protected]
Telephone: fifteen billion twenty-one million five hundred and sixty-two thousand five hundred and thirty-nine
Address: Room 118, Block B, No. 348 Huajiang Road, Shanghai
Current location: Home page of Dewei Chuang > news information > How to use CPAD in OXYGEN software>

news information

How to use CPAD in OXYGEN software
Release time: 22-12-10 22:13 Number of views: twenty-six

stay In OXYGEN software Use CPAD

After OXYGEN 5.6, connecting CPAD does not need to load DBC, but provides a CPAD Decoder plug-in unit . All CPADs can be connected directly. This plug-in can be used in OXYGEN Make the following settings in : - switch CPAD Baud rate of the module - Read module properties - Edit module Channel settings - Change module sampling rate

Of course, it is also supported to use the CPAD module after loading the DBC To connect CPAD, follow these steps

Connect CPAD module to CAN interface and open channel setting ( reference resources chart four point three zero ).  

Select baud rate ( reference resources chart four point three zero

If you don't know CPAD The baud rate can be changed several times until a signal enters ( reference resources chart 4.30) 

Confirm that the CAN bus is connected to the 120 Ω terminal resistor or select the internal terminal option as True ( reference resources chart four point three zero

When the baud rate is selected correctly, click Select to add decoding ( reference resources chart four point three zero )

 image

Fig. 4.30: add to CPAD decoder

In addition, CPAD The decoder plug-in can also be accessed through “+”- Button. To do this, choose the correct CAN Bus channel, Press “+” , Select CPAD Decoder , press “Add”( As shown in the figure four point three one ).

 image

Fig. 4.31: +” Add CPAD decoder in option


After adding CPAD decoding , The connected CPAD and its channel will be displayed on the channel list ( reference resources chart four point three two ). If necessary Yes, you can select different CAN Port to change port options For example, when CPAD switches to a different port as chart four point three two . The baud rate of the module can also be changed here ( reference resources chart four point three two ). Ensure change CAN Bus baud rate and positive Accurately receive and decode data references chart four point three zero .

 image

Fig. 4.32: CPAD Decoder settings

be careful : If one or more connected modules cannot be found in the list, they may have different baud rates, . change CAN Bus baud rate until the missing module is detected and the module baud rate is changed to the expected baud rate. In order to obtain A simpler workflow allows users to disconnect all modules except the missing ones.

CPAD The specific properties of can be CPAD Found in each channel setting of ( Reference drawing four point three three ):

 image

Fig. 4.33: CPAD attribute


You can use the CPAD Edit channel in channel settings (see Fig. 4.34 ):

 image

Fig. 4.34: CPAD Channel settings


CPAD The sample rate of can be changed in the Sample Rate column of the channel list ( Reference drawing four point three five ):

 image

Fig. 4.35: change CPAD sampling rate