How to OXYGEN DAQP and HSI modules are used in the software
4.6.1 adopt ORION Card will DAQP/HSI Module connected to the measurement system
• DEWE-ORION-xx16-xxx boards If DAQP/HSI Module Pass DEWE-ORION-xx16-xxx The board is connected to the measuring system, enter DAQ Hardware settings, confirm protect ORIONDAQ Series hardware and DAQP Series are enabled ( As shown in the figure four point three six ) ( Ensure that the correct driver is installed, and And takes effect after the software starts .
• DEWE-ORION-xx22-xxx and DEWE-ORION-xx24-xxx boards If DAQP/HSI Module Pass DEWE-ORION-xx24-xxx or DEWE-ORION-xx22-xxx The board is connected to the measuring system, Please enter DAQ Hardware settings to ensure ORIONDSA Series hardware and DAQP Series are enabled ( Reference drawing four point three six ) ( Software Effective after restart ) Ensure that the correct drive is installed .
Fig. 4.36: stay DAQ Enabled in hardware settings ORION DAQ/DSA series
4.6.2 adopt TRION-1802/1600-dLV Connecting the DAQP/HSI module
Fig. 4.37: stay DAQ Enabled in hardware settings DAQP and TRION Hardware
• Confirm driver installation is complete
• If the driver is successfully installed, DEWE2-EXPLORER will appear in the system start menu
4.6.3 Edit module address
Fig. 4.38: Edit module address
• Enable connected serial port ( reference resources ① chart four point three eight ).
• Select the appropriate module output range in Advanced Settings ( reference resources advanced setting ).
• Click the Edit Module Location button ( reference resources ② chart four point three eight ).
Fig. 4.39: Module editing interface
• Select the appropriate serial port and edit the address ( As shown in the figure four point three nine ). If the module is connected to multiple serial ports, you must repeat the coding for each serial port Cheng. The following window appears:
Fig. 4.40: Edit module address
• Press DAQP/HSI Modular ID Button until the module is added . For all DAQP The module repeats the process. When finished, press Stop editing by pressing close&Scan window ( As shown in the figure four point four one ) Or start programming as an additional serial port
F ig. 4.41: Complete module editing
• Now? OXYGEN Will be taken from DAQP The module reads the actual settings and writes them to the channel settings in the software
be careful : Click "Scan Module" to scan only the programmed modules and store the actual module settings • The module will appear in the channel list, and you can set the channel
Fig. 4.42: DAQP/HSI Modules and TRION-1802-dLV Channel list after communication
Note:
– ORION The counter channel of the card is not supported in OXYGEN
– CAN The bus is supported in OXYGEN and can be found in the channel list