Application of Dewitro power analyzer in the detection of anti islanding protection performance of energy storage converter
Release time: 23-01-16 11:24 Number of views: thirty-seven
Dewei Chuang Data acquisition system Application of PLC in islanding protection performance test of energy storage converter
Test equipment for anti islanding protection performance of energy storage converter meeting GB/T34133 standard
Anti islanding protection performance detection circuit
Island protection performance test Equipment used:
DEWE3-PA8
TRION3-1820-POWER-4
CT-1000
DEWE3-PA8 integrated host:
The integrated sensor power supply can be 8 Current sensor supply ; 4 pieces can be added TRION3 -1820-POWER-4 power acquisition card conducts 16 voltage and 16 current tests; The range of high-voltage channel can reach ± 2000Vpeak, and the range of current channel can reach 40Apeak; Test precision: DC ± 0.02% * reading ± 0.02% * range; AC 0.5~1kHz: ± 0.03% * reading without range error; There is no gap storage, and the signal waveform can be viewed without oscilloscope. CT-1000: DC/AC 1000A, basic accuracy:<0.05%
Test method for anti islanding protection performance: use waveform to record the changes of active power, reactive power and current when the switch is disconnected.